Tival Differential Pressure Sensors TST-DD 10.0 / 20.0

Description

Tival Sensors TST-DD 10.0 / 20.0, Differential pressure transmitte is designed for the differential pressure measurement of air and non-aggressive gases in the millibar range. The TST-DD 10.0 / 20.0 is used in numerous processes, for example in process technology, pneumatics or ventilation technology for filter monitoring.

To measure the differential pressure, the open silicon measuring cell of the sensor is directly pressurized on both sides. The process connection of the two pressure sides takes place by means of hose connection with 3.5 mm or 5.5 mm length.

The differential pressure measuring range can be divided in half or doubled in the device by means of bridges. Therefore, the TST-DD 10.0 / 20.0 can be adjusted quickly and easily at any time. Depending on the requirements of the application, the differential pressure transmitter can be designed with or without a display.

The version with display can display the measured value in bar or pascal. The output can be executed as an analog signal with 4 … 20 mA or 0 … 10 V DC, or as a transistor or relay switching output. The total measurement error at room temperature is ? 2.5% FS (optional 1% FS).

Product description Differential pressure transmitter TST-DD 10.0 / 20.0

  • Differential pressure transmitter for air and non-agressive gases
  • With 4 … 20 mA or 0 … 10 V DC analog output
  • Also available with switching output (transistor or relay)
  • Switchable measuring ranges via bridges in the device
  • Available with and without display

Standard differential pressure measuring ranges TST-DD 10.0 / 20.0

(Switchable over bridges in the device)
Nominal differential pressureFactor 0,5Factor 2max. overpressure
(mbar)(mbar)
21420
52,510100
2512,550250
10050200500

Other measuring ranges on request (vacuum measuring ranges possible)Reference : tival-sensors.com