Fuji FLR M-Flow PW Time Delta Ultrasonic Flow Meter based on transit- time measuring method. Making full use of the latest electrics and digital signal processing technologies, we realized the equipment with improved anti-bubble performance high accuracy. The communication function (MODBUS: option) is also applicable.
Fuji FLR M-Flow PW Time Delta Ultrasonic Flow Meter General
- This instrument provides a communication function by RS-485 interface, by which it can transmit and receive data to and from host computer, programmable controller, graphic display panel, etc.
- When using the RS-485 interface, the communication system consists of master station and slave stations. Up to 31 slave stations (this instrument) can be connected per master station.
Note that, because the master station can communicate with only only one slave station at a time, a party to communicate with must be specified by the “Station No.” set at each slave station. - In order that the master station and slave station can communicate, the format of the transmit/receive data must coincide. With this instrument, communication data format is determined by the MODBUS protocol and M-Flow protocol (our M-flow [Type: FLR]).
- Please use an RS-232C ? RS-485 converter in case of designating a personal computer or other devices which have an RS-232C interface as a master station.
Applications
- Homogenous liquid where the ultrasonic signal can be transmitted.
- Bubble quantity: 0 to 12 vol % (For pipe size 50A, water, velocity 1m/s)
- Fluid turbidity: 10000g/L max.
- Type of flow: Fully-developed turbulent or laminar flow in a full-filled pipe
Fuji FLR M-Flow PW Time Delta Ultrasonic Flow Meter Specifications
System Configuration | Sigle-path system of a flow transmitter (Model FLR) and transducer (Model FSS) |
Accuracy | ±1.5% (±1.0% is also available) |
Flow Velocity Range | 0 to ±0.3 … ±10m/s |
Power Supply | 100 to 240V AC +10%/-15%, 50/60 Hz; or 20 to 30V DC |
Ambient Temperature | Flow Transmitter : -20 to +50 ºC |
Transducer: -20 to +60 ºC | |
Power consumption | 15VA max. (AC power supply) |
6W max. ( DC power supply) | |
Analog signal | 4 to 20mA DC (1 point) |
Load resistance: 600? max. | |
Digital Output | Foward total, reverse total, total switch assignable arbitrarily |
Transistor contact (isolated, open collector) | |
Output: 2 point | |
Normal: ON/OFF selectable | |
Contact capacity: 30V DC, 50mA | |
Output Frequency: 1000P/s max. (pulse width: 5, 10, 50, 100, 200, 500, 1000ms) | |
Material | Transmitter: Plastic Alloy |
Transducer: | |
FSSA: PBT(housing), SUS304(Guide rail) | |
FSSC: PBT(housing), Aluminium alloy + plastic (Guide rail) |
Download : Data Sheet Fuji FLR FSS Ultrasonic Flow Meter
Reference: https://www.fujielectric.com/
Other Articles
- Flowma Flowmasonic WUF 620 J Portable Ultrasonic Flow Meter
- Ultrasonic Flow Meter : Prinsip Kerja, Jenis, dan Kelebihannya
- Flowma Flowmasonic WUF 620 CF Clamp On Ultrasonic Flow Meter
- Cara Instalasi Flow Meter Ultrasonic Clamp-on Flowmasonic WUF 500
- Flow meter Air Jenis Ultrasonic clamp on Flowmasonic WUF 500
- Water flow sensor jenis clamp on ultrasonic flow meter
- Flowma Flowmasonic WUF 620 J Portable Ultrasonic Flow Meter
- Flow meter ultrasonic clamp on untuk pipa HDPE
- Flow Meter Ultrasonic Jenis Clamp On Untuk Pipa PVC
- Flow Meter Ultrasonic Clamp on untuk Proses Destilasi Air Laut
- Flow Meter Ultrasonic Portable untuk Mengecek Sistem Pendingin Mesin
- Jarak panjang Pipa pemasangan transducer ultrasonic
- Flow meter ultrasonic yang digunakan untuk sistem pemadam kebakaran
- Flow Meter Ultrasonic yang Digunakan untuk Cooling Tower
- Harga Flow Meter Ultrasonic
- Flexim clamp on Ultrasonic Flow Meter Fluxus
- Fuji FSC Portable Ultrasonic Flow Meter