The Rheonik RHM80 Coriolis mass flow sensor excels in tough applications with high temperatures, pressures, and corrosive fluids. Its heavy-duty construction withstands extreme applications without sacrificing Coriolis meter performance.
- Range: 80 kg/min up to 8000 kg/min
- Pressure: up to 299 bar (4336 psi)
- Temperature: -196°C (-321°F) up to +350°C (662°F)
- Accuracy: 0.1 % of the rate
- Materials: SS 316L / SS 316Ti, Super Duplex – 1.4410, Alloy C22 – 2.4602
- Process Connection: 6″ up to 6″
Features
- Standard pressure ratings up to 341 bar (4946 psi)
- Temperature ratings from -196 to 350°C (-320 to 662°F)
- Mass flow uncertainty down to 0.15%
- Density uncertainty down to 0.5%
- Repeatability better than 0.05%
- Typical measuring ranges between 200 and 8000 kg/min
- Accurately measure low flow rates down to 130g/min
- Unique robust torsion has driven the oscillation system
- Process connection customization available
- Approved for use in hazardous areas
- Stainless steel case
- Remote and compact transmitter versions are available
Applications
Typical applications include:
- Terminal Transfer
- Asphalt/Bitumen and Other High-Temperature Fluids
- Viscous Fluids
- Barge, Ship, Rail Car, and Truck Filling
Benefits
- The torsion oscillator design assures a stable and drift-free measurement with excellent signal-to-noise ratios
- Resilient to external noise and vibration
- Insensitive to pipe pressure changes
- Robust tube wall thickness provides increased operational safety in abrasive applications
- Corrosion-resistant
- Long sensor life is guaranteed due to low mechanical stresses in the meter mechanism
- No moving parts to wear or fail
Performance Data
- Flow Measurement Uncertainty
- Selected Sensors down to ±0.10 % ¹ of rate (Gold Line)
- Standard Sensors down to ±0.15 % ² of rate
- Flow Measurement Repeatability
- Down to ±0.05 % of rate
- Temperature Measurement
- Better than ±1 °C
- Density Calibration (Liquid)
- Selected Sensors down to ±0.0005 kg/liter (Gold Line)
- Standard Sensors down to ±0.001 kg/liter
- Measurement Tube Pressure Ratings
- Its lowest-rated part determines the maximum pressure (Pmax) of a sensor. The lowest rated part can be either the measurement tube (pmax indicated below), the connection block/manifold
(pmax indicated in the mechanical construction section) or the process connection (for pmax see published standards or manufacturer information).
- Its lowest-rated part determines the maximum pressure (Pmax) of a sensor. The lowest rated part can be either the measurement tube (pmax indicated below), the connection block/manifold
Uncertainties and flow measurements turn down
All uncertainty statements refer to reference conditions – the mass flow of water, 18 – 24 °C, 1 – 3 bar in a standard temperature, pressure, and material configuration sensor. The sensor can be used to measure gas – uncertainty values for gas equal to the liquid value plus 0.3 %. Reference conditions for gas are mass flow of natural gas, 18 – 24 °C, 35 to 100 bar in a standard temperature, pressure, and material configuration sensor.
The turn-down capability from the Qnom of the flow sensor is mainly driven by its zero-point stability. At the very low end of the measuring range, the uncertainty (u) is dominated by the zero point stability. The zero point stability of a standard sensor is 0.000036 kg/min (0.000079 lbs/min). The zero stability of a Gold Line sensor is 0.000019 kg/min (0.000042 lbs/min).
For flow Q ? zero stability / (calibration uncertainty/100) u = calibration uncertainty
For flow Q < zero stability / (calibration uncertainty/100) u = (zero stability/Q) x 100
Uncertainties from environmental and process conditions
- If sensors are not zeroed at operating conditions, minor additional uncertainties can arise from elevated temperatures and pressures: ±0.00308 % of maximum flow per °C and ±0.0208 % of maximum flow per bar.
- Process temperature effect on density: additional uncertainty of ±0.000641 g/cm³ per °C difference from calibration temperature with standard density calibration and of ±0.000073 g/cm³ per °C difference from calibration temperature with enhanced density calibration. This effect can be mitigated by a simple field density adjustment at operating conditions.
- Process pressure effect on mass flow: The effect of pressure on flow measurement is 0.001 % of the rate per bar. Compensation is possible by pressure sensor input (analog input or digital write) or manual value entry into the transmitter.
- Process pressure effect on density: The effect of pressure on density measurement is 0.00012 g/cc per bar. Compensation is possible by pressure sensor input (analog input or digital write) or manual value entry into the transmitter.
General Specifications
Nominal Flow (Q???)* | 5000 kg/min (11023 lb/min) |
Maximum Flow (Q???)* | 8000 kg/min (17637 lb/min) |
Typical Minimum Flow (Q???)* | 100 kg/min (176 lb/min) |
Operating Temperature | Fluid temperature range options cover applications from -196°C to +350°C (-320°F to +662°F). For integral transmitter versions please refer to the transmitter datasheet |
Ambient Temperature | -50°C to 80°C (-58°F to 176°F) |
Pressure Ratings | Up to 341 bar / 4946 psi – dependent upon material |
Electrical Connection Sensor | M20 x 1.5 standard cable entry for JM, SM terminal box versions |
w/o Integral Transmitter | Optional entries available : ½” NPT or M25 x 1.5 (only for SM) or ¾” NPT (only for SM) |
Max. cable length to remote RHE transmitter 100 m / 328 ft | |
Sensor Enclosure Materials | Stainless steel 304 (standard), SS 316 (optional) |
Coated aluminum terminal box, SS 316 terminal box (optional) | |
Enclosure Type | Protection class IP66 / NEMA 4X with Standard Temperature Range (Option N1/NA); IP65 / NEMA 4 for Extended Temperature Ranges (Option E2 / E3 / H4) |
Wetted Materials | 1.4571 (SS 316Ti), 1.4410 (SuperDuplex) – standard |
2.4602 (Alloy C22) – consult Factory | |
Additional/customer-specific materials available upon request | |
Process Connections | Nearly any – the Rheonik AnyPipeFit Commitment. Consult the factory for types/sizes not listed in this data sheet on the Mechanical Construction pages |
Pressure Rating Compliance | Europe – PED: Module A2, Module B3.1+C2 |
Canada – CRN: Canadian Registration Number | |
Certifications and Approvals | ATEX / IECEx Approvals for Zone 0, 1 (details see page 10) |
North American Approvals Class I, Div. 1, 2, Gr. A, B, C, D, Zone 0, 1, 2 | |
MID custody transfer approval (OIML R117) | |
American Bureau of Shipping (ABS) Product Type Approval for use on marine vessels | |
Testing and Inspection | All sensors are hydro-tested, calibrated, and supplied with a traceable calibration certificate. Customized calibration and testing services are available |
Project Documentation and QA, Services | Rheonik offers a full set of services for large and complex engineering projects. |
Typical services offered are, but not limited to: | |
•Certificates of origin and conformity, mill certificates | |
•Data books including WPAR, WQS, NDT, test & quality plans, functional testing, calibration procedures, customized packing, factory acceptance, etc. | |
•Painting to project specification | |
•Start up and commissioning services on/offshore | |
Options | Enclosure heating for high-temperature applications |
Cleaning for oxygen service, … | |
For more consult the factory |
Kind of Coriolis Mass Flow Meter from RHEONIK
Small Size Coriolis Mass Flow Sensor
Ideal for embedded systems and precise small-flow applications
- RHM 015 Low Flow Mass Flow Meter flow rate
- RHM 02 Low Flow Mass Flow Meter flow rate
- RHM 03 Low Flow Mass Flow Meter flowrate
- RHM 04 Low Flow Mass Flow Meter flow rate
- RHM 06 Low Flow Mass Flow Meter flowrate
- RHM 08 Low Flow Mass Flow Meter flow rate
Medium Size Coriolis Mass Flow Sensor
Suited to industrial and process flow control and monitoring
- RHM 12 Mass Flow Meter flow rate
- RHM 15 Mass Flow Meter flow rate
- RHM 20 Mass Flow Meter flow rate
- RHM 30 Mass Flow Meter flow rate
- RHM 40 Mass Flow Meter flow rate
Large Size Coriolis Mass Flow Sensor
Perfect for material movements in small and wide-scale operations
- RHM 60 Coriolis Flow Meter flow rate
- RHM 80 Coriolis Flow Mass Meter flow rate
- RHM 100 Coriolis Flow Mass Meter flow rate
- RHM 160 Coriolis Flow Mass Meter flow rate
The types of Coriolis Mass Flow Transmitter
- Rheonik RHE16 Coriolis mass flow transmitter Compact Multifunction
- Rheonik RHE15 Profibus DP Module
- Rheonik RHE21 explosion-proof field mount Mass Flow Transmitter
- Rheonik RHE 26 Coriolis Mass Flow Transmitter
- Rheonik RHE 27 Coriolis mass flow transmitter
- Rheonik RHE28 Field / Wall Mount Coriolis mass flow transmitter
- Rheonik RHE45 Compact Mount Coriolis Mass Flow Transmitter
- Rheonik RHE42 Coriolis Mass Flow Transmitter
For information Price, stock and other please contact: WMA
Other Articles
- Flow Meter Open Channel Untuk PLTU
- Instalasi Flow meter ultrasonic clamp on untuk air dingin mesin chiller
- Prosedur Instalasi Flow Meter Electromagnetic
- Meteran air Jenis flow meter Ultrasonic
- Flow meter ultrasonic clamp on untuk pipa HDPE
- Flow Meter Ultrasonic Jenis Clamp On Untuk Pipa PVC
- Harga Coriolis Mass Flow Meter
- Perlunya Resetting dan Kalibrasi Flow meter secara berkala