Aplisens APRE-2000 PD Smart Differential Pressure Transmitter is applicable to the measurement of differential pressure of gases, vapors and liquids. The active element is a piezoresistant silicon sensor separated from the medium by separating diaphragms and a specially selected type of manometric fluid.
The special design of the active sensing element ensures that it is able to withstand pressure surges and overloads of up to 250, 320 or 413 bar. Electronics in the casing with a degree of protection IP65, IP66.
Aplisens APRE-2000 PD Metrological Parameters
- Accuracy: ?±0,1% of calibrated range
- Long term stability (for the nominal measuring range):
- ? accuracy for 3 years
- ? 2 x accuracy for 5 years
- HS version: ? accuracy for 6 years
- or ? 2 x accuracy for 10 years
- Thermal error
- < ±0,08% (FSO) / 10°C
- max. ±0,3% (FSO) in the whole compensation range
- Thermal compensation range: -25…80°C
- Zero shift error for static pressure
- 0,01% (FSO) / 10 bar for ranges no. 3, 4, 5, 6, 7, 9
- 0,03% (FSO) / 10 bar for range no. 8
- 0,06% (FSO) / 10 bar for ranges no. 1, 2
- 0,01% (FSO) / 10 bar for ranges no. 2, 8 in HS version
- 0,02% (FSO) / 10 bar for range no. 10
Zeroing the transmitter in conditions of static pressure can eliminate this error.
- Response time: 16…230ms (programmable)
- Additional electronic damping: 0…60 s
- Error due to supply voltage changes: 0,002% (FSO) / V
Aplisens APRE-2000 PD Electrical Parameters
- Power supply: 7,5…55 VDC (Ex ia 7,5…30 VDC)
- Output signal: 4…20 mA + HART
- Load resistance: R[? ]? Usup [V] – 7,5V / 0,0225A
- Resistance required for communication min. 240 W
Materials
- Wetted parts: SS316L, Hastelloy C276
- Diaphragms: SS316L, Hastelloy C 276, Au
- Casing: SS304
Operating Conditions
- Operating temperature range (ambient temp.):
- -25…85°C
- Exi a version -25…80°C
- Medium temperature range -25…120°C
- over 120°C – measurement with use an impulse line or diaphragm seals
- up to 100°C – PED version
- up to 100°C – version for 413bar static pressure
CAUTION: the medium must not be allowed to freeze in the
impulse line or close to the process connection of the transmitter
Download Datasheet: Aplisens Smart differential pressure transmitter APRE-2000 PD
Reference: aplisens.com
Another Article:
- Aplisens Smart differential pressure transmitter APRE-2000 ALW
- Aplisens Smart differential pressure transmitter with APRE-2200ALW or APRE-2200
- Aplisens Smart Level Transmitter APC-2000ALW/L
- Tracer 1000™ 3G LTT1-3G 3rd (up to 60ft) Flocorp-Generation Radar Level Transmitter
- Tracer Air™ LTTA Non-Contact Radar Level Transmitter (up to 98ft), Flocorp-Level Transmitter