Bamo LCF3/CF4 Level Controllers and Indicators

Description

Bamo LCF3/CF4 Level Controllers and Indicators is mounted above the tank. Against the liquid height, the float transmits the level through an angle drive to a vertical stem. The stem actuates on a pointer associated with a graduated dial to display the level in the tank. Depending on the model, it can also act on contacts, and/ or a potentiometer which will deliver an ohmic value image of measurement.

Bamo LCF3/CF4 Level Controllers and Indicators Features

  • Tank height from 250 to 3000 mm
  • Transmission: angle drive
  • Fitting: male 2” BSP
  • Head housing: IP 54
  • 3 possible functions:
    • Direct reading
    • With 1 to 3 contacts, potential free
    • Output signal: continuous resistive signal (?)

The instrument is available with several functions

  • 1 continuous signal output (?)
  • Display for direct reading of level
    • For commodity, the level is visible on 2 opposite sides.
  • 1 to 3 contacts (potential free)
    • Option: on request up to 5 contacts

The complete system is supplied ready to install and to use.

Application

Gauge for level display and filling control.

  • Diesel in storage tank or day-tank
  • Stored lubricating oil, glycol water, rainwater

Particularly suited to meet the needs and conditions of use for storage tank or day-tank of diesel generators.

Bamo LCF3/CF4 Level Controllers and Indicators Specification

MaterialsSteel, Nylon
Float: Foamed PVC
Flange sealCork gasket
Fitting2” BSP, male
Head housingIP 54
Operating pressureAtmospheric
Operating temperatureBetween 0 and 40 °C
Measuring distancesModel 1: From 250 up to 1100 mm
Model 2: From 1100 up to 3000 mm
Scale:Liters
Contact(s)Default setting:
Filling function: ON at 50 % and OFF at 80 % capacity
(2-way contact, 10 A, 230 V, potential free)
– High level: 90 % capacity
(Change-over contact, 10 A, 230 V, potential free)
– Low level alarm: 30 % capacity
(Change-over contact, 10 A, 230 V, potential free)
On request: Factory adjustment between 10 and 90%.
Output, resistive signalFrom 0 to 90 ? (approx., ±15 %)


Download Data Sheet: Level Controllers and Indicators CF3/CF4 Series

Ref: bamo.eu

Another Article: