Description
The EX90-series battery-powered, insertion electromagnetic flow meter is designed for use with conductive fluids in 4”–12” pipe. The EX90’s stainless steel body allows the meter to operate in a wide range of temperatures, pressure, and corrosive or dirty environments.
The EX90 is highly suitable for difficult applications. With no moving parts, these meters can be used in “dirty water” applications where debris would foul a mechanical meter. If the EX90 meter is used with a programmable controller, the output signal can be fed direct, with no other conditioning required.
Rate and total units can be set via the front panel touch keypad by the user. Bidirectional flow is standard with totals available in forward, reverse, net, batch forward and batch reverse. The EX90 is battery powered and an output cable is available for transmitting the pulse signal to remote devices.
The EX90 includes a Seametrics saddle that has been designed to accommodate a wide range of pipe sizes and types while ensuring correct placement in the pipe. In addition, an optional internal data logger allows local storage of flow history.
Features
- Direct replacement for propeller meters
- Easy to install
- Less pipe obstruction
- No moving parts or bearings to replace
- No routine maintenance
- Pulse Output Standard
- 4-year battery life
- Economical
APPLICATIONS
- Municipal water
- Water/Wastewater treatment
- Reuse/Reclaim water
- Industrial processes
- Cooling towers
- Pump towers
- Dewatering
Specificaition
Pipe Size | 4” to 12” | ||||
Materials | Sensor Body | 316 SS | |||
Electrodes | Hastelloy | ||||
Housing | Powder-coated diecast aluminum | ||||
Electrode Cap | PVDF (Kynar®) | ||||
O-Ring | EPDM | ||||
Temperature | Operating | 10? to 140? F (-12? to 60? C) | |||
Storage | -40? to 158? F (-40? to 70? C) | ||||
Fluid Temp. | 32? to 200? F (0? to 93? C) | ||||
Pressure | 200 psi (14 bar) | ||||
Flow Rate | 0.5 – 4.5 m/sec (1.64 – 14.8 ft/sec) (Low flow cutoff .15 m/sec; .49 ft/sec) | ||||
Calibration Accuracy | 0.5 – 4.5 m/s (1.64-14.76 ft/sec) | +/- 2% of reading | |||
0.3 – 0.5 m/sec (0.98 – 1.64 ft/sec) | +/- (2% of reading + 0.25% of full scale) | ||||
Display | Type | 128×64 dot-matrix LCD | |||
Digits | 5 Digit Rate | 8 Digit Total | |||
Units Please Note: | Rate Volume Units | Rate Time Units | Total Volume Units | ||
Gallons Liters Barrels (42 gallons) Cubic Feet Cubic Meters Million Gallons1 Mega Liters1 Imperial Gallons Million Imperial Gallons1 | Second Minute Hour Day | Gallons Gallons x 10 Gallons x 100 Gallons x 1000 Million Gallons Liters Kilo Liters Mega Liters Barrels (42 gallons) Cubic Meters | Cubic Meters x 1000 Cubic Feet Cubic Feet x 1000 Million Cubic Feet Imperial Gallons Imperial Gallons x 1000 Million Imperial Gallons Acre Inch Acre Foot Fluid Ounce | ||
Bidirectional | Forward Total, Reverse Total, Net Total, Batch Forward, Batch Reverse2 | ||||
Power | One lithium 7.2V ‘D’ size battery pack, replaceable. | ||||
Scaled Pulse Output | Signal | Current sinking pulse, isolated, 36 Vdc at 10 mA max | |||
Pulse Rates | User-scalable from 0.1 to 99,999.9 volume units/pulse. Pulse width varies with output frequency, 150 pulses/sec max | ||||
Cable | Optional Output Cable | 20ft (6m) standard length polyurethane jacketed cable—for power and outputs. (Lengths up to 200’ (60 m) available.) | |||
Conductivity | >20 microSiemens/cm | ||||
Empty Pipe Detection | Hardware/software, conductivity-based | ||||
Regulatory | Certified to NSF/ANSI standard 61 and NSF 372 (Stainless only with EPDM O-ring. Viton pending). | ||||
Environmental | IP 67 |

More Information please click :
- Flow Meter Open Channel Untuk PLTU
- Instalasi Flow meter ultrasonic clamp on untuk air dingin mesin chiller
- Prosedur Instalasi Flow Meter Electromagnetic
- Meteran air Jenis flow meter Ultrasonic
- Flow meter ultrasonic clamp on untuk pipa HDPE
- Flow Meter Ultrasonic Jenis Clamp On Untuk Pipa PVC
- Harga Coriolis Mass Flow Meter
- Perlunya Resetting dan Kalibrasi Flow meter secara berkala
- Jenis Flow Meter Berdasarkan Prinsip Kerja dan Aplikasinya
- Penentuan Kapasitas Flow Meter Pada Aliran Air
- Flow Meter Ultrasonic Clamp on untuk Proses Destilasi Air Laut
- Flow Meter Ultrasonic Portable untuk Mengecek Sistem Pendingin Mesin
- Penggunaan Flowmeter Ultrasonic Pada Pengolahan air limbah
You must be logged in to post a comment.