Bamo NivOil® / 12V DC Alarm System for Oil-Water Separators

Overview

Bamo NivOil / 12V DC Alarm System designed for the monitoring of hydrocarbon fluids separators, the alarm device NIVOIL may be connected to 1, 2, or 3 sensors.

  • Hydrocarbon layer thickness sensor to detect when the maximum thickness is reached.
  • Overfill sensor to detect when the fluids are on the highest level.
  • Sludge layer sensor for alarming when maintenance is necessary.

The 3 sensors may be connected to any input of the alarm device NIVOIL. Any combination of the sensors can be wired. The instrument recognizes automatically the level sensor type. An LED indicates the sensor type on the diagram on the front board. The alarm device NIVOIL has a built-in buzzer; it is possible to disable its function.

Bamo NivOil Alarm System Features

  • Low power consumption – 10…27 V DC power supply input
  • Zone 0 ATEX certified (Zone 2 for the alarm device location)
  • Solar-powered or standard electric battery – Energy saving mode adjustable (control frequency adjustable from 6 min up to 9 days)
  • 3 inputs, for any NIVOIL probes
  • Automatic recognition of type probe
  • 3 relay outputs with audible alarm

Low power consumption

This model working with a 10 to 27 V DC power supply has low energy consumption. It is designed for the use of a solar-powered battery or any standard electric battery (consumption is 0.1 W – 12 V DC – with 3 sensors connected with one complete control cycle per hour).

Sleep mode

This mode is adjustable by modifying the frequency of the control cycle (from 6 minutes up to 9 days). A continuous control mode could be switched on when there is no limit on consumption.

ATEX certified

All the components are ATEX-certified. The sensors are for a location in zone 0 and the alarm device corresponds to a zone 2.

Alarm System Specification

Main power supply:10…27 V DC
Power consumption:0.1 W / 12 V DC (3 sensors connected and 1 control cycle per hour)
Housing protection:IP65, according to EN 60529
Temperature limits:-20…+60°C
Sensor inputs:3 inputs with automatic sensor type detection
for hydrocarbon fluids layer thickness, overfill level, sludge layer level
Monitoring:The alarm device NIVOIL has an auto-diagnostic of measuring loop
a short circuit or a broken cable.
Display and signals:1 function signal LED (green) on each channel
1 alarm signal LED (red) on each channel
Built-in audible alarm, disabled by DIP switch configuration
Front panel:2 push buttons for diagnostic test and alarm clearance
Outputs:3 relay outputs, Power switch 250 V AC as a maximum / 3A, Potential free change over contacts
ATEX Certificate:BVS 10 ATEX E 011 / The alarm device may be mounted in Ex area, zone 2
Ex-protection class:II 3 (1) G Ex nAC [ia Ga] IIB / IIA T4 Gc (Intrinsic safety)
CE MarksAccording to EC directives (72/23/EEC), Low Voltage Guidelines: RL 2006/95/EG & RL93/68/EWG,
EMV Guidelines: RL 89/336/EWG (EN 61326)
ATEXRL 94/9/EG (ATEX 95)
EN 60079-0 (General requirements) – EN 60079-11 (Intrinsic safety) – EN 60079-26 (Group II; category 1G)

Download Data Sheet: Alarm System for Oil-Water Separators NivOil®/ 12 V dc