LMag-F Litre Meter Electromagnetic Flanged Flow Meters

Description

Cost-effective flanged electromagnetic flow meter. The flanged LMag-F range of mag flow meters represents great value for money, and meters are available for pipe sizes from 3” to 12” with ANSI pattern flanges. The electrodes are non-fouling, and LMag-F meters can be mounted with as little as 2x pipe diameter of upstream straight pipe run. Three styles are available depending on output and display position.

The electromagnetic flowmeter uses Faraday’s Law of electromagnetic induction to measure the process flow. When an electrically conductive fluid flows in the pipe, an electrode voltage E is induced between a pair of electrodes placed at right angles to the direction of the magnetic field.

Specify meter-mounted or remote display for flexibility in positioning. Meters are CE certified and certified to NSF Standard 62 for Drinking Water Systems. LMag-F meters are IP68 rated and may be continuously submerged to 3m depth. Bidirectional flow reading is standard with totals available in forward, reverse, net flow, batch forward flow, and batch reverse flow. Batch totals can be reset.

The pulse output is standard on all models and a 4-20ma passive current loop is standard on the LMag-Fp. In addition, 4-20mA loop, HART protocol, high-speed digital, and Modbus® are optional on externally powered units, depending on the model. User-friendly backlit display & user interface Rate and total indication are standard. Rate and total units and pulse scaling can be set via the front panel touch keypad.

Magnetic flowmeters operate under the principle of Faraday’s Law of Electromagnetic Induction to measure liquid velocity. Following Faraday’s Law, magnetic flowmeters measure the velocity of conductive liquids in pipes, such as water, acids, caustic, and slurries. In order of usage, magnetic flowmeters are used in the water/wastewater industry, chemical, food and beverage, power, pulp and paper, metals and mining and pharmaceutical applications.

Electromagnetic flow meters are a type of velocity or volumetric flow meter that operates pursuant to Faraday’s law of electromagnetic induction – which states that a voltage will be induced when a conductor moves through a magnetic field.

User-friendly backlit display & user interface

Rate and total indication are standard. Rate and total units and pulse scaling can be set via the front panel touch keypad.

LMag-F mag flow meters Features

Typical applications:

  • Water/wastewater treatment
  • Pump skids
  • Pumping stations
  • Packaged plants
  • Filtration systems
  • Reclaimed water
  • Easy setup
  • Minimal straight pipe
  • Mounted or remote rate & total
  • Tamper-evident seal
  • Certified to NSF/ANSI standard 61
  • IP68 rated
  • No moving parts

LMag-F Litre Meter Electromagnetic Flanged Flow Meters Specification

Pipe sizes:3”, 4” 6”, 8” 10”, 12”
Flanges:150 lb, ANSI pattern
Pressure:10.3 bar
Temperatures:Operating-12º to 60º C
Storage-40º to 70º C
Accuracy:±0.75% of reading, ±0.025% of full-scale flow from low flow cutoff to maximum flow rate of 10 m/sec
Low flow cutoff:0.5% of maximum flow rate
Materials:BodyDuctile cast iron, powder coated (3”), Welded steel, epoxy coated (4-12”)
LinerNoryl® (3”), Santoprene flange/polypropylene liner body (4-12”)
Electronics housingPowder-coated diecast aluminium
Electrodes316 stainless steel
O-RingEPDM
PowerDC Power9-36 Vdc @ 250 mA max, 30 mA average
Battery backup (not primary power)DC powered units: Two lithium 3.6V ‘D’ batteries, replaceable AC powered units: One 9V alkaline battery, replaceable
AC Power (remote and direct models)85-264Vac, 50/60Hz, 0.12A
Battery (LMag-Fb only)One lithium 7.2V ‘D’ size battery pack, replaceable
Scaled pulse output:SignalCurrent sinking pulse, isolated, 36 Vdc at 10mA max
Pulse ratesUser-scalable from 0.1 to 99,999.9 volume units/pulse
Options4-20mA current loopIsolated, passive, 24Vdc, 650 ? maximum current loop
HART/4-20mAHART protocol over 4-20mA line
High speed digital outputIsolated, open collector, 24Vdc (remote and direct only)
Serial communicationsIsolated, asynchronous serial RS485 (Reconfigurable for RS232 or 3.3V CMOS), Modbus® RTU protocol (factory selectable)
Cable:Power/Output cable6m standard length polyurethane jacketed cable—for power and outputs (lengths up to 60m available)
Remote display cable6m standard length polyurethane jacketed cable—for connection between meter and remote display (lengths up to 60m available)
Conductivity:>20 microSiemens/cm
Empty pipe detection:Hardware/software, conductivity-based
Regulatory(EN 61326), 4”-12” certified to NSF/ANSI standard 61 60°C; 3” certified to NSF/ANSI standard 61 Cold Water 23°C
EnvironmentalNEMA 6P, IP68 (3m depth, continuously)

Download Datasheet: LMag-F Litre Meter Electromagnetic Flanged Flow Meters

Reference:litremeter.com