E2FQ Omron Chemical resistant Proximity Sensor

Chemical resistant Proximity Sensor

E2FQ Omron Chemical resistant Proximity Sensor use high-frequency oscillation. They resist heat, chemicals, and water better than Rectangular Sensors. They are available in both shielded and unshielded models.

E2FQ Omron Chemical resistant Proximity Sensor Components detect, measure, analyze, and process various changes that occur on productions sites, such as changes in position, length, height, displacement, and appearance. They also contribute to predicting and preventing future events.

Features

  • Housing and mounting are made of Fluororesin resistant to chemicals.
  • Maximum sensing distance: 10

Rating and Specifications

Model

Item

E2FQ-X2E1 E2FQ-X2D1 E2FQ-X5E1

E2FQ-X5D1, E2FQ-X5Y1

E2FQ-X10E1

E2FQ-X10D1, E2FQ-X10Y1

Sensing distance 2 mm ±10% 5 mm ±10% 10 mm ±10%
Set distance 0 to 1.6 mm 0 to 4 mm 0 to 8 mm
Differential travel E1/Y1 Models: 10% max. of sensing distance, D1 Models: 20% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 3.)
Standard sensing object Iron, 12 ´ 12 ´ 1 mm Iron, 18 ´ 18 ´ 1 mm Iron, 30 ´ 30 ´ 1 mm
 

Response frequency *

E1 Models: 1.5 kHz D1 Models: 800 Hz E1 Models: 600 Hz D1 Models: 500 Hz E1 Models: 400 Hz D1 Models: 300 Hz
Y1 Models: 25 Hz
Power supply voltage (operating voltage range) E1 Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Y1 Models: 24 to 240 VAC (20 to 264 VAC), 50/60 Hz

D1 Models: 12 to 24 VDC (10 to 36 VDC), ripple (p-p): 20% max.

Current consumption E1 Models: 17 mA max.
Leakage current D1 Models: 0.8 mA max., Y1 Models: 1.7 mA max. (at 200 VAC)
 

Control output

Load current E1 Models: 200 mA max., D1 Models: 5 to 100 mA, Y1 Models: 5 to 300 mA
Residual voltage E1 Models: 2 V max. (Load current: 200 mA, Cable length: 2 m) Y1 Models: Refer to Engineering Data on page 3.

D1 Models: 3 V max. (Load current: 100 mA, Cable length: 2 m)

Indicators E Models: Detection indicator (red), Y Models: Operation indicator (red), D Models: Operation indicator (red), Setting indicator (green) (NO only)
Operation mode (with sensing object approaching)  

E1/D1/Y1 Models: NO (Refer to the timing charts under I/O Circuit Diagrams on page 5 for details.)

Protection circuits E1 Models: Load short-circuit protection, Reverse polarity protection, Surge suppressor, D1/Y1 Models: Surge sup- pressor
Ambient temperature range Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
 

Voltage influence

E1 Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range D1 Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±20% range Y1 Models: ±1% max. of sensing distance at rated voltage in the rated voltage ±10% range
Insulation resistance 50 MÙ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength E1/D1 Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case Y Models: 4,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant
Connection method Pre-wired Models (Cable length: 2 m)
Weight (packed state) Approx. 70 g Approx. 130 g Approx. 170 g
 

 

 

 

Materials

Case  

 

Fluororesin

Sensing surface
Clamping nuts
Toothed washer Zinc-plated iron
Cable Vinyl chloride
Accessories Instruction manual

Download Catalog: E2FQ, Omron-Chemical-resistant Proximity Sensor

Ref: Omron.co.id

Share