The Hengesbach TPF 200/201 Level and pressure transmitters are suitable for taking pressure and filling level measurements in pipelines and containers. The wide range of hygienic process connections enables use in all applications in the food and pharmaceutical industries.
The vacuum-proof measuring cell with stainless steel membrane works on the basis of the piezoresistive measuring principle The TPF pressure transmitters are designed to measure from -1/0โฆ0.35 to -1/0โฆ100bar. Special measuring ranges are also available on request. Given the nature of the design for long-term medium temperatures of up to 125ยฐC / 200ยฐC, CIP and SIP cleaning methods can be used on the transmitters. The high protection classes of IP67 and IP69K also mean that the devices can be safely cleaned on the outside with foam and a high-pressure cleaner and that moisture is reliably prevented from entering the device.
The TPF pressure transmitters are suitable for taking pressure and filling level measurements in pipelines and containers. The wide range of hygienic process connections enables use in all applications in the food and pharmaceutical industries. Customer-specific process connections are also possible on request.
The vacuum-proof measuring cell with stainless steel membrane works on the basis of the piezoresistive measuring principle The TPF pressure transmitters are designed to measure from -1/0โฆ0.35 to -1/0โฆ100bar. Special measuring ranges are also available on request. Given the nature of the design for long-term medium temperatures of up to 125ยฐC / 200ยฐC, CIP and SIP cleaning methods can be used on the transmitters. The high protection classes of IP67 and IP69K also mean that the devices can be safely cleaned on the outside with foam and high-pressure cleaners and that moisture is reliably prevented from entering the device. For additional protection against moisture, the electronics are fully encapsulated in the housing.
Features:
- High precision 0.05% fs, turn down 10, vacuum safe
- Wide range of process connections for hygienic applications
- Optional with hartยฎ-protocol
- Tank linearisation for standard tank shapes and special designs thanks to volumetric measurement
- Diagnosis function for monitoring of devices
- Copying of device parameters with easy transfer
- Application strengths: measurement of content of pressurized tanks/vacuum measurements with high temperatures
Specification:
General details | ||||
Device type / measuring principle | TPF 200/201/200H/201H: piezoresistive | |||
Input | ||||
Measuring ranges | TPF 200/201/200H/201H | TPF 200/201/200H/201H | ||
Standard nominal measuring ranges [bar] | relative | OP | absolute | OP |
OP = overload protection [bar] | 0โฆ0.35 | 1 | ||
0โฆ1 | 3 | 0โฆ1 | 3 | |
-1/0โฆ2.5 | 8 | 0โฆ2.5 | 8 | |
Special measuring ranges | -1/0โฆ5 | 15 | 0โฆ5 | 15 |
-1/0โฆ10 | 30 | 0โฆ10 | 30 | |
All measuring cells are vacuum-proof | -1/0โฆ30 | 90 | 0โฆ30 | 90 |
-1/0โฆ100 | 250 | 0โฆ100 | 250 | |
Setting the measuring ranges | Via the keypad of the OPUSi display and operating module / via the integrated on-site display Optional: via HARTยฎ | |||
Setting ranges | Start the measuring | zero: | 0โฆ90% | of the sensorโs nominal measuring span |
Measuring span span: | 10โฆ100% | of the sensorโs nominal measuring span | ||
Burst pressure DIN16086 | ? 4-fold measuring range | |||
Output | ||||
Output signal | 2-wire: 4โฆ20mA with a test circuit connection in the device | |||
Optional: 4โฆ20mA HARTยฎ | ||||
Fault signal | Optional: 3.8mA, 22mA, hold (i.e. holding the last value) | |||
Current limitation | 3.85mA and 21.5mA (normal operation) | |||
Integration time | Continuously selectable between 0 and 300s (setting time after a pressure leap) | |||
Measuring accuracy | ||||
Reference conditions | acc. to DIN IEC 770 | |||
Linearity, hysteresis and repeatability as per the limit point method DIN IEC 770 | ? ยฑ 0.05% of the sensorโs nominal measuring range | |||
Activation time | < 5s (the device will carry out a self-test.) | |||
Setting time (without damping) | < 200ms | |||
Long-time drift | ? 0.2% of the span per year | |||
Thermal hysteresis | ? ยฑ 0.75% beginning of the measuring range / ? ยฑ 0.8% end of the measuring range (VRM) | |||
? ยฑ 0.2% of the sensorโs nominal measuring range / 10K (-20โฆ | +80ยฐC) from 4 bar (PZM) | |||
? ยฑ 0.3% of the sensorโs nominal measuring range / 10K (-20โฆ | +80ยฐC) up to 0.6 bar (PZM) | |||
Conditions of use | ||||
Installation position / calibration position | Any position / standing vertically (position-dependent zero point displacement) | |||
Medium temperature | T1: -40โฆ+125ยฐC (140ยฐC over one hour at the most) | |||
T2: -40โฆ+200ยฐC (high-temperature version) | ||||
Ambient storage temperature | Type 201/201H: | -40โฆ+85ยฐC | ||
Type 200/200H: | -30โฆ+75ยฐC | |||
(Below -20ยฐC cable breakage might occur and the displayโs function may be impaired.) | ||||
Protection class acc. to EN60529 | IP 67 and IP 69K | |||
Electromagnetic compatibility | Sensitivity against interference: acc. to DIN IEC 61000-6-2 | |||
Interference radiation: | acc. to DIN IEC 61000-6-4 | |||
Construction | ||||
Electrical connection | โ Standard: cable screw connection M16x1.5, nickel-plated brass, stainless steel available on request | |||
โ Optional: round plug-in connector M12x1, nickel-plated brass, stainless steel available on request | ||||
โ Optional: angle plug acc. to EN 175301-803 | ||||
โ Optional: reference cable | ||||
Process connection | โ All standard front-mounted process connections and those that are commonly used by the manufacturer | |||
โ Membrane, flush-welded on the front, CrNiSt, other materials available on request |
Download Data Sheet: Pressure and Level Transmitter TPF 200/201
Ref: hengesbach.com