Hengesbach TP 62 Resistance Thermometer QUICKTEMP

Description

Hengesbach TP 62 Resistance Thermometer QUICKTEMP temperature sensor has 2 transmitters in the connection head, which may, for example, be used for indication and registration purposes. In addition, QA tests, repair, and maintenance work are possible without having to interrupt the process and open the measuring point.

The entire device Hengesbach TP 62 including the connection head and measuring insert, can be taken out of the process without loosening the electrical cables. This saves time and resources and creates process security.

The measuring insert is a double PT100 sensor with spring bearings and metallic contacts to ensure good heat transmission and short response times. The design of the Quicktemp system is based on one basic device with various fitting lengths or process connections, assuming defined fitting lengths. For the user, this guarantees a high degree of flexibility, while at the same time minimizing storage costs.

The two standard TE42 transmitters installed have an mA output and can be programmed via the set-up plug. The connection head in the PA is robust and resistant to external environmental conditions (protection class IP 66); it ensures good access, including the cabling of the transmitters.

Hengesbach TP 62 Features:

  • double transmitter (4-20 ma or hard output with 2-wire technology)
  • quality assurance tests and retooling without process interruption and without loosening the electrical wiring.
  • exchangeable measuring insert with spring bearings and metallic contact.
  • various designs for appropriate installation, and adaptation to existing measuring points without design changes.
  • quick response times due to tapered sensor tips

Specification:

General details
Device type/measuring principleTP62…T500 / Pt100 resistor
Measuring insert
Sensor type– 2x Pt100 in accordance with EN 60751, 3-wire
Version– Standard version tmax=400°C
– Mineral-insulated version tmax=600°C, vibration resistant
DimensionsLength 154mm (with T500), Ø=3mm
Output
Version– Temperature transmitter – 2X TE42, 4…20mA, 2-wire (standard)
Transmitter TE42
Supply voltage10 to 35 VDCTemperature drift≤ ± 0.01%
Current requirement≤ 3.5mACalibration temperature+25°C ± 5K
Current limitation≤ 23mAAmbient temperature-40…+85°C
Switch-on delay4sConfigurable start of range< 50% final value
Response time1sAttenuation0…60s, configurable
Fault signal≤3.6mA / ≥21mA, configurableVibration resistance4g / 2…150Hz (according to IEC 60068-2-30)
Voltage change influence≤ ± 0.01%/V of 24V FSProtection classIP00 (installed, see housing protection class)
Circuit type2-wireClimate classCl. C, EN60654-1
Output signal4…20mA or 20…4mA, 2-wireCE conformityEN 61326-1
Load resistance(Vref-10V)/0.022AMeasuring accuracy (typical values)0.2K or 0.08%
Long-term stability≤ ± 0.1K/year (under reference conditions)Measuring current at sensor (normal)< 0.6mA
Linearity error≤ ± 0.1%/Kmax. sensor cable resistance11Ω/wire
Burden influence≤ ± 0.02%/100Ω FSWire compensation with 2-L
Measuring rangeTypePt100, 2L / 3L / 4Lmin. Temperature -200°C
min. temperature span10Kmax. Temperature +650°C
Connecting terminalsScrew clamps (captive screws), wires up to 1.75mm² or 1.5mm² with wire-end ferrules
Measuring accuracy
Pt100 class in accordance with EN 60751– A (Standard)
– AA (1/3B)
Response timesT50≤4…6sec or shorter (design-dependent), other information on request
Conditions of use
Medium temperature-50…400°C (standard), -50…600°C (version with mineral-insulated measuring insert)
Ambient / storage conditions– -40…+85°C (increased risk of cable breaks at less than -20°C)
– Humidity 95%, without condensing (depending on transmitter used)
Protection class acc. to EN60529   IP 67 and IP 69K (depending on design)
Structural design – basic device
Electrical connectionRound plug-in connector M12x1, 4-pin, nickel-plated brass (stainless steel available on request)
Process connectionQuicktemp with screw-in thread G¼“ – for protective sleeves with collar and loose union nut G¼“
SealCaptive O-Ring seal
Materials– Field housing / lid:CrNiSt 1.4301 (304)
– Housing seal:FPM (Viton®)
– Measuring insert:CrNiSt 1.4571
– O-Ring seal:FKM
Structural design – protectivesleeves
Process connection– Clamp connection
– Weld-in solutions
– Conical coupling / threaded coupling DIN 11851
– Female union / threaded coupling DIN 11864-1
– VARIVENT® type N, type F
– 1“ ISO 228 thread
– Other connections such as elastomer-free sealing systems, Ingold connectors, 1“ ISO 228 thread, …
Materials– Sleeve body and collar CrNiSt 1.4404
– Union nut CrNiSt 1.4305
Shape of tip– Standard
– Tapered
Max. process pressureDepending on the design, min. PN10 (optionally up to PN80, pay attention to design)
Accessories for Quick temp TP62…T500
Configuration kitTZ42-USB with HengCom software (as downloaded at http://www.hengesbach.com)
CertificatesCalibration certificate, conformity declaration, material products in accordance with EN 10204

Download Data Sheet:Resistance Thermometer TP 62