Ascon Controllers and Indicators

Ascon Controllers and Indicators Experience and innovation are the basis of this range of instruments, capable of responding to any performance requirement.

From the “entry-level” controller with the innovative “Sensitive-Touch” keyboard to the more sophisticated microprocessor controllers with PID algorithm, in different formats, standard and not. The most complete range you could wish for! Advanced single and multiloop controllers and programmers, multifunction and with built-in independent timer, in all formats.

The Products of Ascon Controllers and Indicators

Controllers and Programmers (Kube Series)

KM1 - Controller with independent timer
KM1 – Controller with independent timer

KUBE series: the evolution that has something more! Pocket size, energy saving, and advanced functions:

  • evergreen – for Energy Saving
  • evoTune – for “trouble-free” adjustment
  • evoTools – code-based configuration for fast commissioning and programming key for instant parameterization
  • User calibration for sensor position compensation
  • Independent timer function with 5 operating modes
  • Hour meter/working days with 2 functions and programmable alarm
  • Calculation of power and energy consumption (Wattmeter)
  • Freely customizable parameter sequence

Technical Specifications

FunctionController
Dimensions48 x 48 mm
Display2 display with 4 digit 3 dynamic colors
Power supply24 Vac/Vdc, 100… 240 Vac
Inputs0/1… 5 V, 0/2… 10 V, 0/4… 20 mA, Pt100, Pt1000, PTC-NTC, Thermocouple, Universal
Number of outputs1, 2, 3, 4
OutputsRelay and/or SSR control
Digital inputs1, 2
Independent timerYes
InterfaceRS 485 Modbus Slave, TTL Modbus
Special functionsDigital retransmission, Hours/Days worked, ON time, Power on delay, Soft start, Transmitter power supply, User calibration, Wattmeter
ControlON/OFF and PID single or double action
ExtractabilityNot extractable, With fixed terminal block, With removable terminal block
CertificationsCE, UL

Controllers (TLK Series)

It is a multistep microprocessor digital controller (stepped) typically used to control multi-compressor refrigeration units, but also for other systems having several separate actuators that condition the process variable.

Multistep controller, 4 outputs and RS485
Multistep controller, 4 outputs and RS485

Technical Specifications

FunctionMultistep controller
Dimensions78 x 35 mm
Display1 display with 4 digit
Power supply12 Vac/Vdc
InputsTC, infrared sensors, RTDs, Thermistors, signals in mV, V, mA + 2 digital
Number of outputs4
ControlON/OFF, Neutral Zone, Proportional
CommunicationTTL Modbus + RS 485 isolated RS 485, Modbus Master
CertificationsCE, UL

2 Loop Controllers (Gammauno Series)

  • This controller is configurable as 1 loop, cascade, ratio, or 2 independent loops.
  • It is universal, and very powerful but simple to use.
  • It is equipped with Autotune as an aid to the commissioning of the system and serial communication for insertion into a distributed control network.
  • It is complete because the possible variants are always present.
Controller with 2 individually configurable loops
Controller with 2 individually configurable loops

Technical Specifications

FunctionController
Dimensions96 x 96 mm
Display3 display
Power supply24 Vac/Vdc, 100… 240 Vac
Inputs0/1… 5 V, 0/2… 10 V, 0/4… 20 mA, Delta T Pt100, Pt100, Thermocouple, Universal
Number of outputs1, 2, 3, 4, 5, 6
Outputs0/1… 5 V, 0/2… 10 V, 0/4… 20 mA, Relay and/or SSR control, Servomotor
Digital inputs1, 2, 3
Auxiliary inputPotentiometer
Retransmission output0/1… 5 V, 0/2… 10 V, 0/4… 20 mA
InterfaceRS 485 Modbus Slave
Special functionsTransmitter power supply
ControlDouble action with 2 PID, ON/OFF and PID single or double action, Servomotor
ExtractabilityBy the front
CertificationsCE

DIN Rail 2 Loop Controllers (Delta Series)

  • Two loops in the room of one.
  • The single bus for power supply and serial communication, the total extractability, the easy replacement even under voltage, the digital input to use remote controls, and the possibility of acquiring or regulating up to two analog variables make the D2 line deltadue®, a powerful and flexible instrument, suitable for solving various problems of signal management from the field.
  • In combination with the DX module, it can be inserted in Profibus DP® and DeviceNet® networks, with the possibility of automatic reconfiguration.
Temperature controller with two isolated loops
Temperature controller with two isolated loops

Technical Specifications

FunctionController
DimensionsDIN rail mounting
Power supply24 Vac/Vdc
Inputs0/4… 20 mA, Delta T Pt100, Pt100, Thermocouple, Universal
Number of outputs1, 2, 3, 4
OutputsRelay and/or SSR control
Digital inputs1
InterfaceRS 485 Modbus Slave
Special functionsSoft start, User calibration
ControlON/OFF and PID single or double action
ExtractabilityBy the front
CertificationsCE, UL

Indicators (J Series)

  • Advanced indicator with 5-digit display with configurable red/green color.
  • It can have up to 2 inputs + 3 digital inputs, serial communication with RS485 Modbus protocol, up to 4 relay alarm outputs with ISA-A sequence, analog signal retransmission, and display of positive and negative peaks.
5-digit indicator with 1 input, 2 alarms, and Modbus RTU
5-digit indicator with 1 input, 2 alarms, and Modbus RTU

Technical Specifications

FunctionIndicator
Dimensions96 x 48 mm
Display1 display with 5 digits 2 configs.colors
Power supply24 Vac/Vdc, 100… 240 Vac
Inputs0/4… 20 mA, Delta T Pt100, Pt100, Universal
Number of outputs1, 2
OutputsRelay and/or SSR control
InterfaceRS 232 Modbus Slave, RS 485 Modbus Slave
Special functionsTransmitter power supply
ExtractabilityBy the front
CertificationsCE, UL

Oven Control (TCO Series)

  • This is the ideal instrument for the bakery sector as it is able to separately manage the “ceiling” and “floor” with the relative partitions, but also the lighting, the extractor, the steamer, and the steam injection.
  • It also provides for the storage of 8 different cooking programs and can have up to 7 relay outputs, up to 4 inputs for thermocouples, and 3 configurable digital inputs.
  •  Thanks to the internal clock it is possible to program the oven’s automatic switch on at the desired time, the cooking time, and also the automatic switch off.
  •  Finally, it offers the possibility of having an RS485 serial communication interface.
Controller for cooking ovens
Controller for cooking ovens

Technical Specifications

FunctionController
Dimensions72 x 144 mm
Display3 display with 3+3+4 digit
Power supply230 Vac
InputsTC J-K + 3 digital
Number of outputs7
ControlMotorized actuators, ON/OFF
CommunicationRS 485 isolated
ProgrammerYes
CertificationsCE

Universal Indicators (TLI Series)

  • Indicators with universal input, 4 relay outputs, or static relay driving (SSR) can be used for signaling alarms.
  • One of these outputs can also be of the analog type and can be used for the retransmission of the measurement signal.
  • As an alternative to the OUT4 output, it is possible to have a configurable digital input.
  • It also has particular functions such as the memory of the maximum and minimum peaks, the Hold function, the possibility of setting the zero value and/or carrying out the calibration by self-learning for input from the potentiometer, the possibility of establishing the sampling rate of the measure (from 8 to 64 acquisitions per sec.).
Indicator with universal input
Indicator with universal input

Technical Specifications

FunctionIndicator, Transmitter
Dimensions48 x 48 mm
Display1 display with 4 digit
Power supply24 Vac/Vdc, 100… 240 Vac
Inputs0/1… 5 V, 0/2… 10 V, 0/4… 20 mA, Potentiometer, Pt100, PTC-NTC, Thermocouple
Number of outputs1, 2, 3, 4
OutputsRelay and/or SSR control
Auxiliary inputCurrent transformer, Potentiometer
Retransmission output0/2… 10 V, 0/4… 20 mA
InterfaceRS 485 Modbus Slave, TTL Modbus
Special functionsTransmitter power supply
ExtractabilityNot extractable, With fix terminal block
CertificationsCE, UL

 

Alarm/Events Indicators (X-Series)

The alarms/events are shown on the 3-digit display and can be detected by the device via 10 digital inputs for free voltage or voltage (24 Vac/Vdc) contacts whose operation is fully configurable. The instrument can also be equipped with a relay and an internal buzzer for the acoustic signaling of alarms/events. A capacitive “Sensitive Touch” keyboard (Model X31SL) is also available on request.

Alarms and generic events Display
Alarms and generic events Display

Technical Specifications

FunctionIndicator
Dimensions78 x 35 mm
Display1 display with 3 digit
Power supply24 Vac/Vdc, 100… 240 Vac
Inputs1 digital
Number of outputs1
OutputsRelay
Digital inputs1, 10, 2, 3, 4, 6
InterfaceTTL Modbus
Special functionsAcoustic alarm (buzzer)
ExtractabilityNot extractable, With fix terminal block, With removable terminal block
CertificationsCE