EUROSENS Dominator AF replaces the sensors with analog output to 5V, analog output to 10V, with frequency output in the range of 500 – 1500 Hz.
- High-precision measurement
- Built-in temperature compensation
- Output signal type can be adjusted
- Strong electronic circuit protection
- Efficient packaging, installation, and sealing
- Modular build
- Sealed automobile connector on the sensor body

Dominator fuel level sensors are designed to minimize the operating costs of fuel consumption monitoring system for the entire period of its operation.
- Powerful electronic module protection. External power voltage protection up to 170 volts.
- The modular design makes it easy to provide technical support for installed sensors. We can easily localize the problem either in the sensor “head” or in sensor electrodes because electrodes can be disconnected from sensor “head”.
- The modular design allows not only to cut the sensor for a specific vessel but also to extend the electrode. It’s useful when you reinstall the system to another object. Sensors of the traditional non-modular design can’t be extended and once shortened electrodes can’t be replaced.
- If the fault is in the “head” of the sensor – replacement can be done even by the end-user – the owner of the equipment. Thanks to bayonet, fast-lock replacement is very easy and takes about 10 minutes. It is much cheaper than travel costs of installation staff.
- Easy sealing of the sensor from disconnection cable and sensor removal.
- The electrodes can be easily disassembled and cleaned. Sensors of conventional design can be contaminated in the gap between electrodes that require complex maintenance. Dominator electrodes can be cleaned by the customer without warranty violations.
- After sensor “head” replacement you don’t need to make tank calibration again (unlike traditional design sensors).
- Warranty term – 5 years.
Specification
Power voltage, V | 9 – 32 |
Reverse polarity protection | Yes |
Max error | ±1% |
Temperature range,°C | -40 – +85 |
Output voltage, V | 0,5 – 9,5 |
Output frequency, Hz | 500 – 1500 |
Seal rating | IP 67 |
Galvanic isolation | up to 500V |