TE KPSI 720 Hydrostatic Level Transducer

TE KPSI 720 Hydrostatic Level Transducer is a submersible hydrostatic level transducer specifically designed to meet the rigorous environments encountered in liquid level measurement and control. It can be configured to perform to specifications under most adverse, reactive conditions. Every KPSI Transducer utilizes a highly accurate pressure sensor assembly specifically designed for hostile fluids and gases.

The assembly is integrated with supporting electronics in a durable waterproof housing constructed of 316 stainless steel or titanium. The attached electrical cable is custom manufactured and includes para-aramid synthetic fiber members to prevent errors due to cable elongation and a unique water block feature that self-seals in the event of accidental cuts to the cable. Each vented reference transducer is shipped with a Superdry Vent Filter that prevents moisture from entering the vent tube for one year without maintenance, even in the most humid environments.

TE KPSI 720 Hydrostatic Level Transducer Features

  • Custom polyurethane or ETFE cable lengths
  • Welded 316SS or titanium body
  • Custom level ranges up to 700 ft. (210 m) H2O
  • Multiple analog outputs
  • Multiple nose piece styles
  • Optional lifetime lightning protection
  • Long life vent filter or aneroid bellows
  • Available molded cable seal

Applications

  • Lift stations
  • Pump control
  • Level control
  • Surface water monitoring
  • Landfill leachate
  • Well monitoring
  • Groundwater monitoring

TE KPSI 720 Hydrostatic Level Transducer Specification

Parameter Comment
Level Ranges
Full-scale level ranges
(Intermediate level ranges are available)
2.3 thru 700 ft. H20 (0.70 thru 210 m H20)
10 thru 700 ft. H20 (3 thru 210 m H20)
35 thru 700 ft. H20 (10 thru 210 m H20)
Vented Gage Reference
Sealed Gage Reference
Absolute Gage Reference
Proof pressure 1.5 x FS
Burst pressure 2.0 x FS
Static Performance
Static Accuracy
(combined effects of non-linearity, hysteresis
and repeatability, best fit straight-line method)
±0.25% FSO BFSL method
Resolution ±0.0001% FS
Electrical
Excitation 9-28V – VDC output
9-28V – mA outpu
15-28V – VDC output
10-28V – VDC output
0-5V, 0-2.5V, 0-4V
4-20
0-10V
1.5-7.5V
Input current 20 mA max
3.5 mA max
For mA output
For VDC output
Output 4-20mA, 0-5 VDC, 0-2.5VDC,
0-4VDC, 0-10VDC, 1.5-7.5VDC
Zero Offset Rezero after installation for optimum accuracy. Span is not affected (See application note on website)
Output Impedance See loop diagram for mA output
20 ohm for VDC output
Insulation Resistance 100 mega-ohm at 50 VDC
Circuit Protection Polarity, surge/shorted output
Physical
Approximate Weight 0.5 lbs. (227 g) transducer
0.05 lbs./ft. (79 g/m) cable
Cable jacket material Polyurethane (standard)
ETFE (optional)
Cable pull strength 200 lbs. (90 kg)
Cable number of conductors 4
Cable conductor size 22 AWG
Cable seal Molded polyurethane
FKM Gland
For polyurethane cable
For ETFE cable

Download Datasheet: TE Connectivity KPSI 720 Submersible Level Transducer