Description of Gastec PD-1B-2 Permeater
PD-1B-2 Gastec A fluoro resin tube that holds premium liquefied gas is called a permeater permeation tube.

A certain amount of gas can be held in the tube by osmosis, which allows liquefied gas to enter the tube wall in time increments when the tube is exposed to a particular temperature. As a result, by maintaining the tube at a fixed temperature and injecting a consistent amount of dilution gas, a carrier gas flowing at a constant speed (for calibration purposes) can be constantly formed.
Because the concentration of the calibration gas is calculated by measuring the amount of dilution gas and the change in weight of the permeation tube, this approach is very dependable. Highly reactive gases including ammonia, hydrogen sulfide, and chlorine can also be produced using this dynamic approach. There are numerous varieties of permeation tubes, as the table below illustrates, and they are frequently utilized due to their capacity to deliver a consistent supply of calibration gas.
Features of Gastec PD-1B-2 Permeater
- Highly reliable because concentration levels are determined by calculating weight loss based on.
- Many types (both organic and inorganic) of low-concentration calibration gases) can be generated.
- Gas for calibration of all organic solvents (as long as they are stable in their liquid state or at normal temperatures) can be generated.
- Gas for calibration can be generated continuously for longer periods of time.
- Calibration gas can be easily generated in a wide range of concentrations.
Specification of Gastec PD-1B-2 Permeater
Target gas to be generated | Permeation tube method: As a characteristic of the gas, the boiling point ranges between -60 and +30?. In addition, the stable, high-purity material used for the permeation tube enables the calibration gas to be generated. Diffusion tube method: As characteristics of the liquid, the vapour pressure over the temperature range of 25-50? lies within the range of 5-400 mmHg. In addition, the stable, high-purity material used for the permeation tube enables calibration gas to be generated. |
Accuracy of the generated gas | +/- 3% |
Flow adjustment range | 0.2-10L/min (Tapered tube 0.2-2L/min, 1-10L/min) |
Temperature setting | 5-step setting: 25, 30, 35, 40, 50ºC (When the difference between room temperature and the set temperature is 3ºC or less, cooling with city water or some other method is necessary.) |
Temperature setting accuracy | +/- 0.15ºC |
Dimensions | 301(H) x 306(W) x 270(D)mm |
weight | 13kg |
Power supply, Max. power consumption | AC100V 50/60Hz 180W |
Dilute gas, Standard gas connection port | Tubes of O. D. 6 mm, and I. D. 4 mm |
For More Information and Price : Gastec PD-1B-2 Permeater
Read More Articles:
- Flush-Mounted Pressure and Level Transmitter Hengesbach PZM 100/101
- Flush-Mounted Pressure Transmitter Hengesbach TCF050D
- Weldable Resistance Thermometer Type TP13 Hengesbach
- Diaphragm Manometer PC 100/160 Hengesbach
- Flush-Mounted Pressure Transmitter VRM050D Series Hengesbach
You must be logged in to post a comment.