Hengesbach G Conductivity transmitter Condutec is used for the measurement of conductivity or concentration in liquids, e.g. in CIP-lines or other processes in the beverage industry. High accuracy and resistance against contamination of the electrode are achieved by using 4 electrode conductivity cells. The instrument can be operated directly and user-friendly at the graphic display. The switching output can be freely programmed; the Condutec is available either as a compact unit or split version (for strong vibrations or significant heat radiations).
Hengesbach G Conductivity Transmitter Features:
- measurement / control of conductivity or concentration in liquids
- available as compact unit or split version
- output for conductivity and temperature 4 – 20 ma
- measuring range programmable from 0… 500 ms/cm
- sensor can be sterilized up to 140°, 1 H
- various process connections are available, e.g. hygienic design versions
Specification:
General information | ||
Device type/measuring principle | CONDUTEC / conductivity measurement | |
Input | ||
Measuring range | 0…500mS/cm | |
Measuring rate | approx. 3/seconds | |
Temperature sensor | Pt1000 acc. to DIN IEC 751 | |
Temperature measuring range | -40…+160°C | |
Conductivity output | ||
Output signal | 2-wire: 4…20mA | |
Cell constant | programmable in the range of 0,08…4,0 | |
Standard error | ± 0,5% from measure value ± 2 digit | |
Temperature coefficient | < 100ppm/°C | |
Temperature compensation | linear programmable in range 0,0…8,0%/°C | |
Temperature output | ||
Output signal | 2-Leiter: 4…20mA | |
Burden | RA=(UB-14V) / 0,02A | |
Alarm output | ||
Transistor | 2x transistor output, 14…30V DC, max. 60mA | |
Voltage drop | < 2V | |
Measuring range switching | ||
Ri | > 10kΩ | |
MB1 active | U=0…3V DC | |
MB2 active | U=12…30V DC | |
Conditions of use | ||
Installation position | unsuitable for transom mounting; otherwise arbitrarily | |
Medium temperature | -10…+120°C (short duration 140°C for max. 30 min) | |
Environmental temperature | 0…+50°C | |
Protection class EN60529 | IP 65 | |
Electromagnetic compatibility | acc. to EN 50022, DIN IEC 61000-4-3/4/5 | |
Construction | ||
Electrical connection | – Standard: M20x1.5 cable screw connection | |
– Optional: M12x1 round plug-in connector, nickel-plated brass (stainless steel available on request) | ||
Process connection | – Clamp DIN 32676, DN25/DN32/DN40 | |
– Tapered Union with grooved union nut DIN 11851, DN25 | ||
– Tapered Union with grooved union nut DIN 11851, DN40 | ||
– Conical coupling with grooved union nut DIN 11851, DN50 | ||
– Conical coupling with grooved union nut DIN 11851, DN65 | ||
– modular system PZM | ||
– VARIVENT® Ø=50mm (F) | ||
– VARIVENT® Ø=68mm (N) | ||
Materials | – Housing: | Polyamide, PA6-GF/GK 15/15 |
– Front cover display: | Polyester | |
– Process connection/sensor: | PEEK, PVDF, CrNi Wkst. 1.4404, graphite, gasket EPM 80 – with FDA certification | |
Type | – Compact: | sensor and transmitter assembled as one unit |
– Splitted: | sensor and transmitter separate; connected by 5m, 10m or 20m cable | |
Display | – LCD-dot display, 3.8mm height, 2 lines with 16 characters | |
– Display range conductivity: 500…9999 Digit | ||
– Unit conductivity adjustable: µS/cm, mS/cm, kΩ/cm, MΩ/cm | ||
– Unit temperature adjustable: °C, °F | ||
Auxiliary energy | ||
Supply voltage | 14…30V DC, 2-wire system |
Download Data Sheet: Conducticity Transmitter Condutec G
Ref: hengesbach.com
Another Article:
You must be logged in to post a comment.