Microsensor Corp MDM4901FL Differential Pressure Transmitter
Microsensor Corp MDM4901FL Differential Pressure Transmitter

Microsensor Corp MDM390 Differential Pressure Transmitter

Description

Microsensorcorp MDM390 differential pressure transducer is produced by putting the OEM differential pressure sensor into full-welded housing with G1/4 female for both positive and negative cavities.

The transducer could be mounted into a measuring tube through a G1/4 female pressure port or a leading tube. It is a cable connection. The transducer could be widely used in industrial process control, flow measurement, medical devices, air dynamical measuring, liquid pressure instruments or pneumatic plants, etc.

Microsensorcorp MDM390 Features

  • OEM differential pressure sensor;
  • Full solid insulation, high stability, reliability, and accuracy;
  • Constant current supply;
  • static pressure 20MPa;
  • G1/4 female pressure port;
  • Liquid, gas, and other media differential pressure measurement;
  • Compact size.

Notes

  1. We suggest installing a tri-valve between the measured point and transmitter so that the measured media can be put on positive and negative cavities slowly This would help the transducer work safely and reliably;
  2. We suggest installing a differential pressure transducer horizontally;
  3. Please pay attention to if the transducer’s range and static pressure could be suitable for measured pressure;
  4. Cable length: we provide standard 1.5m cable free of charge, the extra cable should be paid additionally;
  5. Please be careful that the pressure of the positive cavity is bigger than the negative

Specifications

@1.5mADC,25?
Pressure range0~35kPa…3.5MPa
Zero output?2mVDC
Output signal?60mVDC
+overpressure2 times FS
-overpressure1 time FS or 1MPa(min. value is valid)
Static pressure?20MPa
Static pressure effect?0.05mV/100kPa
Accuracy1±0.25%FS(typ.)±0.5%FS(max.)
Zero drift<±0.02mV/?
FS drift<±0.02%FS/?
Relative humility±0.3%FS/year(typ.)±0.5%FS/year(max.)
Compensation temp.0? ~50?
Operation temp.-10? ~70?
Storage temp.-20? ~85?
 Response time+ pressure cavity<3kHz

– pressure cavity<2kHz

DiaphragmStainless steel 316L
HousingStainless steel 1Cr18Ni9Ti
O-ringViton
Cable?7.2mm PVC cable
Insulation resistor100M??100VDC
ProtectionIP65
1: Non-linearity + Hysteresis + Repeatability

Download Datasheet: MDM390, Microsensorcorp-Differential Pressure Transmitter

Ref: Microsensorcorp.com