Overview
- Advanced level sensing algorithm suppresses the noise level and artifacts and enabled stable measurement.
- One main unit handles two sensors at once. Two different types of sensors can be installed and each may measures different range.
- Data logging function to micro SD TM.
- Flow measurement by measuring catchment level is possible.
Specifikasi Honda Electronic HD1200
| Model No. | HD1200 | |
| Channel | 2 | |
| Frequency | 10 to 60 kHz (select by sensor) | |
| Measurement object | liquid / powder | |
| Resolution | Measurement | 1 mm |
| display | 1 mm | |
| Accuracy | ±0.25%?F.S. | |
| Data refresh rate | 2 sec. approx. (depends on sensor) | |
| Power source | Voltage | 100 to 240 V AC?±10 % |
| Power consumption | 10 VA | |
| Display | LCD with backlight | |
| Output | Alarm | 4 points / channel |
| 250VAC, 5 A (relay contact) | ||
| 4-20mA current | Resolution: 1/4000 | |
| (Max. load resistance 600?) | ||
| Interface | RS-485 (max. distance: 1200 m or less) | |
| RS-232C (max. distance: 10 m or less) | ||
| Memory | microSDTM *1 | |
| Operation temperature | -20 to 70? | |
| Material | ABS | |
| Protection | IP66 equivalent | |
| Dimension (WxDxH mm) | 176?84?237 | |
| Weight | 1.8 kg | |
NOTE : Weir type flowmeter is available on CH1
*1 : microSDTM is a trademark of SD Card Association
| Model No. | Sensor | |
| TS40-5 | TS40T-5 | |
| Frequency | 40 kHz | |
| Measurement range(1/2 value for powder) | 0.3 to 20? | 0.3 to 15m |
| Directive angle (half of full angle) | 12°(-6dB)8°(-3dB) | 22°(-6dB)16°(-3dB) |
| Operation temperature | -20 to 70? | |
| Material | Epoxy/silicone/ PP | PVDF |
| Protection | IP68 equivalent | IP68 equivalent |
| Dimension (mm) | dia. 84×90 | dia. 98×87 |
| Sensor cable length | 5m | |
| Weight | 500g | 860g |
| Mounting screw | R1 (PT1) | |
| G1 (PF1) | ||
NOTE :
- Weir type flowmeter is available on CH1*1 : microSDTMis a trademark of SD Card Association
- TS40T-5 is chemical resistant.
- ?The sensors cannot be used in hydrofluoric acid environment.
- * Contact us if sensor cable extension is required.
Baca Juga
- Clamp-on Flow Meter WUF 100 CF untuk PLTU
- Flow meter untuk buangan pipa Jain Technology Xonic 100LO
- Flow Meter Ultrasonic Clamp on Flowma WUF300 CF
- Flow Meter Air Limbah 3 inch Flowma WMAG 21
- Flow Meter Electromagnetic untuk Kalibrasi
- Ultrasonic Clamp on Flow Meter Flowma WUF400 CF
- Pengertian, Cara Kerja, Aplikasi Oval Gear Flow Meter
- Flowma WTF67 Low-cost Turbine Flow Meter
- Flow meter Air Limbah WMAG30 10 Inch High Grade
- Prinsip Kerja, Aplikasi, dan Keuntungan Ultrasonic Doppler Flow Meter
- Clamp on Ultrasonic Gas Flow Meter Xonic 100GC