Flowma SMP131-DLD Differential Pressure Transmitter

Descriptions of Flowma SMP131-DLD Differential Pressure Transmitter

LEEG SMP131-DLD Differential Pressure Transmitter is a high-performance pressure transmitter with international leading technology meticulously designed by Flowma. The sensor is located on the top of the metal body. It stays away from the medium interface to realize mechanical isolation and thermal isolation. Glass sintering sensor wire realizes high-strength electrical insulation of the metal base.

Flowma SMP131-DLD Differential Pressure Transmitter
Flowma SMP131-DLD Differential Pressure Transmitter

It improves the capability of the flexibility of the electronic circuit and transient voltage resistance protection. All these original encapsulation technologies enable SMP858-TST to easily cope with extreme chemical occasions and mechanical load and own strong resistance to EMI, sufficient to respond to the most rigorous industrial environment applications.

Advantages

The dual-diaphragm overload structure can easily cope with high overload tests, 355° rotation display module, friendly button parameters operation function, Accurate filling fluid technology eliminates effects of temperature and static pressure, High strength metal electrical protection housing meets the most rigorous environmental application, Strong transient voltage resistance to protect terminal module, External three buttons menu function enables site operation and does not affect the degree of electrical protection, more safely and conveniently, Beautiful appearance, fully show the fashion sense of science and technology.

Features

  • Measuring range: 10kPa-3.5MPa
  • Output signal: 4-20mA, 4-20mA+HART, 0.5-4.5VDC, Modbus-RTU/RS485, others
  • Reference accuracy: ±0.2% URL, ±0.5% URL, optional ±0.1% URL
  • Process connection: M20*1.5(M), G1/2(M), G1/4 (M), 1/2-14NPT(M)…
  • Measuring medium: Liquid, gas, or steam
  • Media temperature: -30-80?
  • Electrical connection: DIN43650, IP65

Applications

  • Process control system
  • Machine building

Specifications

  • Measuring range: 10kPa-3.5MPa
  • Output signal: 4-20mA, 4-20mA+HART, 0.5-4.5VDC, Modbus-RTU/RS485, others
  • Reference accuracy: ±0.2% URL, ±0.5% URL, optional ±0.1% URL
  • Process connection: M20*1.5(M), G1/2(M), G1/4 (M), 1/2-14NPT(M)…
  • Measuring medium: Liquid, gas, or steam
  • Media temperature: -30-80?
  • Electrical connection: DIN43650, IP65

Checkout now: Flowma SMP131-DLD Differential Pressure Transmitter