Hengesbach TPS Smalline Pressure Transmitters

Overview

Thanks to their design, the flush-mounted Hengesbach TPS Smalline pressure transmitters are suitable for pressure and level measurements with little dead space, even with crystallizing or viscous media. The Hengesbach TPS Smalline Pressure Transmitters in stainless steel housings are available in protection class IP 65 and can optionally be encapsulated. The electrical connection is made via a cable socket or alternatively via an M12 connector.

Hengesbach TPS Smalline pressure transmitters High-temperature versions in continuous operation up to 200 ° C are available. Vacuum resistance is given. The compact standard housing is made of stainless steel. Corresponding weld-in sleeves and application-specific process connections are available.

In addition to flush versions for sanitary and general industrial applications, versions with a pressure gauge connection and attached diaphragm seals are also available. The devices of the Hengesbach TPS Smalline pressure transmitters are suitable for many applications in the industrial sector due to the wide range of connection options.

Features:

  • with internal and external measuring cell
  • ideal for broadband industrial applications for process printing
  • Measuring ranges from 0.35 bar to 30 bar, for relative and absolute pressure measurements
  • Use of food and pharmaceutical compliant materials
  • optional for high medium temperatures up to 200 ° C

Specification:

General Information
Manufacturer/ DeviceHengesbach / Pressure Transmitter TPS
Measuring Principle/ Device TypeTPS piezoresistive, For Pressure and Level Measurement
Entrance
Measuring RangeTPS
Normal Size (bar)RelativeISNAbsoluteISN
0,35 bar10,35 bar1
1 bar31 bar3
2,5 bar82,5 bar8
5 bar155 bar15
10 bar3010 bar30
30 bar9030 bar90
Setting Rangezero      ± 10% (FS)
(Via Potentiometer)span     ± 20% (FS)
Overload Protection-1 bar und 3-facher Messendwert, höhere ÜSI auf Anfrage
Burst Pressure10 times the full scale value depending on the device type and nominal measuring range
Output
Output Signal4…20 mA, 2 wire     Load:   ? (VB – 12 V) /0,02 mA
Influence of the river£ ± 0,15% max
Current Limitation25 mA typ., 32 mA max.
Integration Time0 … 20 sec.
Measurement Accuracy
Reference ConditionDIN  IEC 60770
Linearity incl. Hysteresis and Repeatability and n.d Limit Point Method DIN IEC 770? = 0,3% of the value of the nominal measuring. In the case of small absolute pressure measuring ranges, specifications for linearity are particularly necessary
Warm-up time1 sec.
Response Time (without damping)320 ms (mains frequency 50 Hz selected) or 266 ms (mains frequency 60 Hz selected)
Long Term Drift£ 1% v. EW
Repeatability£ 0,05 % v. EW
Hysteresis£ 0,1% v. EW
Thermal HysteresisZero Point and measuring span in the compensated temperature range 0…80°C.
? ± 0,2% of EW / 10 K for nominal measuring range from 4 bar
? ± 0,3% of EW / 10 K for nominal measuring range 0,6 bar
Nominal Position> 1 bar any
Auxiliary Power
Supply Voltage13-36 VDC, max. permissible residul ripple 1 V …
Supply Voltage Influence? ± 0,03%. Supply Voltage Change
Condition Of Use
Medium Temperature-35°C… + 125°C, 140°C max. für 1 h (Type HT für Temperaturen bis 200°C)
Ambient Temperature-35°C… +85°C
Storage Temperature-35°C… +85°C
Protection class acc. EN 60529– IP 65 (with connector according to EN 175301-803 up to A)
– IP 67 (with permanently attached reference cable)
Electromagnetic compatibilityEMC guidelines according to EN 50081-2 / 50082-2 are fulfilled, CE mark
Constructive structure
DesignStandard housing
materialStandard housing made of 1.4301
Process connections made of 1.4404
Electrical connectionStandard: connector acc. EN 175301-803 type A
– optional: permanently connected reference cable, length 1m
– optional: circular connector M12 x 1
Process connectionssee dimensional drawings and ordering information
Filling liquidSilicone oil (food safe) AK100
CertificateDeclaration of conformity on request

Ref: Hengesbach.com

Other Article:

Similar Posts