J. Schneider AKKUTEC 2420-0 1ph
J. Schneider AKKUTEC 2420-0 1ph

J Schneider AKKUTEC 2420-0 1ph

Description

J Schneider AKKUTEC 2420-0 1ph, Single Phase, DC-UPS with Batteries. The battery buffered DC power supply of the series AKKUTEC is working according to the stand-by parallel mode and ensures in connection with a lead-acid accumulator a safe continuous DC power supply in case of mains failure.

The power supply has the following features:

  •  Primary switched power supply with I/U-charging characteristics
  • active power factor correction (PFC)
  • Battery management by micro-controller
  • Battery voltage tracking of the charging voltage by external sensor module (optional)

Display- and control panel for mount in cabinet door or module (optional)

J. Schneider AKKUTEC 2420-0 1ph Technical Data

Input voltage range230V AC -15/+10%
Rated input current:2,7A AC
Input frequency47-63Hz
max. inrush current65A / 3ms
Ouptut voltage19…26,4V DC
Final charging voltage26,4V DC ±0,4%
Charging characteristicsI/U DIN 41773-1
Deep discharge protection and load rejection at19,8V DC ±0,4%
Nominal output current20A DC
Constant current limitation1,05…1,1xIANom
Battery typePb-Akku, wartungsfrei
efficiency88,80%
Ua=26,4V DC, Ia=20A und Ue=230V AC
max. power loss ‘worst-case’82W
Earth leackage current<3,5mA
Fusing primary5A slow acting, 5×20 (internal)
max. pre-fusing10A slow acting
fusing battery load circuit25A slow acting (external)
fusing DC-output25A slow acting (external)
Type of connection primary ‘mains’Combicon-screw-type terminal 2,5mm2
Type of connection sekundary  ‘Ua’, ‘Batt’Combicon-screw type terminal 4mm2
Type of connection interface ‘IO-1…IO-3’Combicon-screw type terminal 1,5mm2
Type of connection Current-Share-Bus ‘CS’Screw type terminal 2,5mm2
Display and messages
‚Netzbetrieb‘ operationLED green illuminates:
·  Mains operation
(UE>UEmin and TInt<TIntmax)
LED green (battery voltage within the monitoring window 21,6< UBatt < 27V DC)
LED green (battery voltage above the monitoring window UBatt  =27V DC
Fehler (fault)LED red
LED illuminates at:
· Battery operation (during mains operation LED is not illuminated)
· UA– error
· Battery circuit interrupted respective high-ohmic (Testintervall 60s)
· Battery low
· Battery reverse poled
· Battery-over-temperature (only in connection with temperature tracking
Signal in- and outputs
Mains operation 1)potentialfree relay-contact, closer, max. contact load 30 V DC/ 0,5A
Fehler 1)potentialfree relay-contact, changer, max. contact load 30 V DC/ 0,5A
 1)potentialfree relay-contact, closer, max. contact load 30 V DC/ 0,5A
 1)potentialfree relay-contact, closer, max. contact load 30 V DC/ 0,5A
Shut-DownShut down of UPS mode
Switch input, referring ot earth, switch level: 24V DC (16-80V DC)
Starkladung (Boost charging)Activation of boost charging (boost charging voltage 28.6V DC)
Switched input referenced to earth, switching level: 24V DC (16-80V DC)
Weight
a)Individual Moduleca. 3 kg
b)19 “ – versionca. 6,0 kg
c)Installation Panel Version (without batteries)ca. 3,8 kg
d)Installation Panel version with 7.0Ah Battca. 9,5 kg
e)Installation panel version with 12.0Ah Batt.ca. 13 kg
Storage TemperatureRecommended 0…30°C,
Permissible 0…50°C
Operating TemperatureRecommended 10…20°C (battery life!),
Permissible 0…40°C
Protective systemIP20
dimensions
Individual module100,5 x 240,5 x 244 mm (W x H x D)
On installation panel340 x 256 x 252 mm (W x H x D)
19“ Rack482,6 x 132,5 x 244 mm (W x H x D)
FixationMounting bracket for mounting plate
UL approvalsNo

Reference : j-schneider.de

Download : Datasheet